Current position:HOME > News > Industry Dynamic

Integrated ceiling bath is broken how to replace

Editor:Switch socket manufacturers _ switch socket join agent _ Yuba join agent _ Zhejiang GELAN Electric Co., Ltd. │ Release Time:2019-03-21 

As long as the product will have a service life, there will be damage, and the integrated ceiling heater is no exception. If the product is damaged during the warranty period, you can ask someone to help repair or replace it; if you have a shelf life, you can only do it yourself, or spend money to ask the master to get it. Today, GELAN Xiaobian will tell everyone that the integrated ceiling Yuba lamp is broken, how to operate correctly.

集成吊顶浴霸

1, the primary interception power supply


Safety first, especially for products that come into contact with electricity, the primary power supply must be blocked when replacing the Yuba bulb.


2, insist on monotony


Do not replace the Yuba bulb with a hand with water, even if the power is broken, it is assumed that the hand with water replaces the Yuba bulb, and the water stays on the bulb without drying. At this time, the separate lamp constitutes a split of the Yuba bulb.


3, replace the heating bulb


Assume that the heating bulb is broken and cannot be lit, and it can be seen that the heating bulb is filled with black gas. Need to rotate to remove the bulb, buy the same bulb and replace it. Need to pay attention to the purchase of the same power bulb, the common Yuba bulb is generally 220V 275W.


4, replace the lighting bulb


If the lighting bulb is broken, remove the four heating bulbs after blocking the power supply, then take off the hanging spring on the side of the heating lamp, and take down the plastic cover of the bathroom to see the bulb. After the bulb is rotated, Just replace it with a new one. It is suggested that we do not force the cover of the Yuba Center. Since some manufacturers' square covers are integrated, it is very difficult to recover after removal.


5, Yuba bulb can not be changed


Integrated ceiling Yuba bulb replacement equipment is required, can not be changed, because the Yuba bulb is explosion-proof, the lighting bulbs are generally 40W, the general bulb may not meet the requirements, for family safety, it is recommended that you consult a professional Yuba manufacturers, Yuba wholesalers to replace.


The above is the step of replacing the integrated ceiling Yuba bulb. If you still have something that is not very clear, you must first clear it and do it. Otherwise, it is recommended to ask someone to help.